Enable or disable the keyboard beep on your Acroprint ATR120r Electronic Time Recorder. This setting controls whether a sound plays each time a key is pressed.
Button Functions
The In-Out buttons on top of the clock serve as function keys in programming mode. The functions are printed on the card door above the column numbers. To enter programming mode, move the switch found on the back of the clock from Run to Prgm.
Button | Function | Purpose |
IN1 | + | Press IN1 to increase the set value by 1. |
OUT1 | - | Press OUT1 to decrease the set value by 1. |
IN2 | Enter | Press IN2 to confirm the set value. |
OUT2 | Back | Press OUT2 to go to the previous setting. |
IN3 | Clear | Press IN3 to cancel the set value. |
OUT3 | Mode | Press OUT3 to move to the next menu. |
To set the keyboard beep on the ATR120r:
- Move the Set switch on the back of the case from Run to Prgm to enter programming mode.
- Press OUT3 (Mode) to enter Mode B000 (Time & Date Settings). Cycle through modes by pressing button OUT3 (Mode).
- Press IN2 (Enter) until you reach Code 07 (Keyboard Beep). The display will begin to flash.
- Press IN1 (+) or OUT2 (-) to set the keyboard beep.
- 00 01: Beep On
- 00 02: Beep Off
- Press In2 (Enter) to confirm the selection. The device will move to programming code 08 (Menu Password).