Set the Day on an M125 Time Recorder Follow
Although this product has been discontinued, we have retained this documentation for your reference. Content is retained for reference purposes only and may no longer be applicable. Feel free to explore our other available products at Acroprint.com.
The date setting for the following models MUST be manually reset to the first of the month each month, following any month with less than 31 days:
- M125 NR4,
- M125 QR4,
- M125 RR4.
Check out this video to see how to change the day/date or follow the steps below.
To set the day/date:
- Unplug the time recorder and remove the cover.
- Make sure the current time setting is between midnight and noon. The lever increases in tension as the day goes on, requiring more force to manually set the time in the afternoon and evening.
- Push down and release the Yellow lever (behind the right side of the clock face) to set the correct day/date. Each push of the lever advances the date by one day.
- Replace the cover, plug in the recorder, and punch a card to verify the correct day/date setting. Repeat steps 1-5 if necessary.